Salam rekan-rekan pendingin kali
ini saya akan membagikan informasi mengenai kode error AC
AUX,berdasarkan pengalaman di lapangan dan forum teknisi ketika
menangani kode error tersebut. semoga bisa membantu rekan-rekan dalam
mengidentifikasi kode error AC AUX dan melakukan perbaikan dengan tepat. berikut penjelasannya
kode error ac aux
kode error ac aux dan penjelasannya
1.HS(Y) HSA(Y) HSB(Y) HSF (Y) HV(Y) HVA(Y) digital display for the series air-conditioner faults:
- kode error ac aux E4 : PG motor feedback is abnormal. The display precedence level: 1
- Kode error ac aux E1 : Plastic temp sensor is abnormal. The display precedence level: 2
- kode error ac aux E3 : Copper temp sensor is abnormal (indoor). The display precedence level: 3
- kode error ac aux E2 : Copper temp sensor is abnormal (outdoor). The display precedence level: 4
2. H (Except KFR-25G/H) H1 HA HB series faults display:
Fault source: PG motor feedback is abnormal
Display mode: Timing light twinkles 4 times in every 8 seconds
The display precedence level: 1
Fault source: Plastic temp sensor is abnormal
Display mode: Timing light twinkles 1 times in every 8 seconds
The display precedence level: 2
Fault source: Copper temp sensor is abnormal (indoor)
Display mode: Timing light twinkles 2 times in every 8 seconds
The display precedence level: 3
Fault source: Copper temp sensor is abnormal (indoor)
Display mode: Timing light twinkles 1 times in every 1 seconds
The display precedence level: 4
3. H(Y) Model air conditioner fault display:
Fault source: PG motor feedback is abnormal
Display mode: Timing light twinkles 4 times in every 8 seconds
The display precedence level: 1
Fault source: Plastic temp sensor is abnormal
Display mode: Timing light twinkles 1 times in every 8 seconds
The display precedence level: 2
Fault source: Copper temp sensor is abnormal (indoor)
Display mode: Timing light twinkles 2 times in every 8 seconds
The display precedence level: 3
Fault source: Copper temp sensor is abnormal (outdoor)
Display mode: Timing light twinkles 1 times in every 1 seconds
The display precedence level: 4
4. EA EC EM EY EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display series ac faults:
- kode error ac aux E4 : PG motor feedback is abnormal
- kode error ac aux E1 : Plastic temp sensor is abnormal
- kode error ac aux E3 : Copper temp sensor is abnormal (indoor)
5. All of the other E series except EA EC EM EY EZ EAA EAD:
Fault source: PG motor feedback is abnormal
Display mode: Timing light twinkles 4 times in every 8 seconds
The display precedence level: 1
Fault source: Plastic temp sensor is abnormal
Display mode: Timing light twinkles 1 times in every 8 seconds
The display precedence level: 2
Fault source: Copper temp sensor is abnormal (indoor)
Display mode: Timing light twinkles 2 times in every 8 seconds
The display precedence level: 3
6. QA QB QD digital display series ac faults:
Fault source: PG motor feedback is abnormal
Display mode: E4
The display precedence level: 1
Fault source: Plastic temp sensor is abnormal
Display mode: E1
The display precedence level: 2
Fault source: Copper temp sensor is abnormal
Display mode: E3
The display precedence level: 3
Fault source: Over-current oprotection
Display mode: E6
The display precedence level: 4
7. QC QQ light display series air-conditioner faults:
Fault source: PG motor feedback is abnormal
Display mode: Timing light twinkles 4 times in every 8 seconds
The display precedence level: 1
Fault source: Plastic temp sensor is abnormal
Display mode: Timing light twinkles 1 times in every 8 seconds
The display precedence level: 2
Fault source: Copper temp sensor is abnormal
Display mode: Timing light twinkles 3 times in every 8 seconds
The display precedence level: 3
Fault source: Over-current oprotection
Display mode: Timing light twinkles 6 times in every 8 seconds
8. Faults display of 18000BTU~24000BTU wall unit series ac non-digital tube displays:
Fault source: PG motor feedback is abnormal
Display mode: Timing light twinkles 1 times in every 8 seconds
The display precedence level: 2
appearance: System turns off
Fault source: Plastic temp sensor is abnormal
Display mode: Timing light twinkles 2 times in every 8 seconds
The display precedence level: 3
appearance: System turns off
Fault source: Copper temp sensor is abnormal
Display mode: Timing light twinkles 8 times in every 8 seconds
The display precedence level: 4
appearance: System doesn’t turns off
Digital tube displays:
Fault source: PG motor feedback is abnormal
Display mode: E1
The display precedence level: 2
appearance: System turns off
Fault source: Plastic temp sensor is abnormal
Display mode: E3
The display precedence level: 3
appearance: System turns off
Fault source: Copper temp sensor is abnormal
Display mode: E2
The display precedence level: 4
appearance: System doesn’t turn off
E1: Temperature sensor of air intake fault
E2: Temperature sensor of outdoor coil fault
E3: Temperature sensor of indoor coil fault
E4: PG motor of indoor unit feedback fault
kode error ac split merk aux
Self-check information: Hint to defrosting
Self-check code of luminotron: Flicker 1 time/1s
Digital self-check code: Indicates “dF“or defrosting indicator displays
Self-check information: Hint to defense against cold wind
Self-check code of luminotron: Flicker 1 time/3s
Digital self-check code: Fan motor picture not running
Self-check information: Failure of room temperature sensor
Self-check code of luminotron: Flicker 2 times/4s (Flicker 2 times/8s)
Digital self-check code: E2/(L2)
Self-check information: Failure of coiled pipe sensor
Self-check code of luminotron: Flicker 3 times/5s (Flicker 1 time/8s)
Digital self-check code: E3/(L1)
Self-check information: Abnormality of outdoor unit
Self-check code of luminotron: Flicker 4 times/6s (luminating)
Digital self-check code: E4/(E5)
Self-check information: Without feedback of internal fan motor
Self-check code of luminotron: Flicker 5 times/7s (Flicker 6 times/8s)
Digital self-check code: E5/(L6)
Self-check information: Zero crossing signal without current
Self-check code of luminotron: Flicker 6 times/8s
Digital self-check code: E6
Self-check information: External feedback failure
Self-check code of luminotron: Flicker 7 times/9s
Digital self-check code: E7
Self-check information: Overheat protection
Self-check code of luminotron: Flicker 8 times/10s
Digital self-check code: E8
Self-check information: Water pump failure
Self-check code of luminotron: Flicker 9 times/11s
Digital self-check code: E9
Aux AC Error Codes and Troubleshooting
Troubleshooting Guide
Problem: The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on
Cause: Since
the air-conditioner is powered on, it will come to working condition as
long as you press the ON/OFF button of the remote control and the
signal is well received.
Problem: The
compressor stops running but the indoor fan motor keeps working when it
is at cooling mode with the indoor temperature higher than set
temperature.
Cause: If
you turn off the air-conditioner and restart it immediately, it will
return to normal in 3 minutes, after that, the air-conditioner will
automatically adjust the indoor fan speed to what you set.
Problem: The compressor works discontinuously at dehumidifying mode.
Cause: The air-conditioner will automatically control the working of the compressor according to the inside temperature
Problem: The air-conditioner dose not work while the LED display is on.
Cause: The
TIMER is set with the air-conditioner,it will be in hold on condition.
If the TIMER setting is cancelled, the air-conditioner will return to
normal working condition.
Problem: The compressor works discontinuously at cooling and dehumidifying mode, and the indoor fan motor slows down.
Cause: The compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from being frozen.